What is a medical X ray high-voltage cable - Newheek X ray Cable

What is a medical X ray high-voltage cable

Wuhan promotes the development of nucleic acid screening for all employees.
On May 11th, the Wuhan Municipal New Coronary Pneumonia Epidemic Prevention and Control Headquarters Epidemiological Big Data and Epidemiological Investigation Team issued the “Emergency Notice on Carrying Out the City ’s New Coronavirus Nucleic Acid Screening” (hereinafter referred to as “Emergency Notice”), in which The New Coronary Pneumonia Epidemic Prevention and Control Headquarters in various districts of Wuhan: After research, it was decided to carry out a “ten-day battle” for the screening of nucleic acids of all new coronavirus in Wuhan. Each district will make arrangements for the nucleic acid screening plan for all staff in its jurisdiction within a 10-day period.
On the morning of the 12th, Peng Mei News confirmed this news from the epidemic prevention and control headquarters in many districts in Wuhan. At present, all districts have formulated implementation plans in accordance with the requirements of the documents and according to the situation in the district.
Surging News was informed that the issuance of this emergency notice was related to the emergence of multiple newly diagnosed cases in the Dongxihu District of Wuhan. It was to strengthen social prevention and control, prevent the rebound of the epidemic, and strengthen the normalization of epidemic prevention and control.
On May 9th and 10th, Wuhan added a total of 6 new confirmed cases of new pneumonia, breaking the record of 35 consecutive days of no new confirmed cases in Hubei Province.
According to the notification of the Wuhan Municipal Health Commission, the six new cases are all living in Sanmin Community, Changqing Street, Dongxihu District, Wuhan City, of which there are two couples. According to expert analysis, there were 20 confirmed cases in this patient community. After organizing experts to investigate and analyze various factors, the etiology should mainly come from the previous community infection.

Regarding medical X ray high-voltage cables, I believe most customers are not unfamiliar. From the name alone, it is actually a cable. Do n’t underestimate it is just a cable. Do you know the specific application of medical high-voltage cables? For most customers may not know how to reply, today I will introduce to you:
High-voltage cable can be widely used in different X-ray machines in medicine, such as C-arm, mobile X-ray, radiography, DR, lithotripsy, X-ray diagnosis, etc. Different high-voltage generators, high-pressure tanks and various industrial non-destructive testing equipment and instruments can be used in industry.
Huarui’s high-voltage cables are divided into two types: 75kv and 90kv, which are medically used for 125kv and 150kv x-ray tube. The conductor material is tinned copper, with a nominal cross-section of 1.8mm², a structure of 19 / 0.35mm, twisted to the left, insulated wire core, and the material is F46. Elastomer high-voltage insulation, gray pvc sheath, semi-conductive elastomer inner shield, 2 layers outer shield. High voltage insulation is better, safe and effective.
x-ray-high-voltage-cable